The hand bidet you
have ordered can be installed in a variety of convenient
locations; either on the left or right side of the toilet. The
only limitations are the length of the hose.
Although we’ve provided the most common fittings, fresh
water outlet fittings and sizes will vary. If needed, we
suggest that you take your unit to the local hardware store to
find the proper size fitting / adapter.
It is also recommended that you install a shutoff valve
similar to the picture below. This will allow you to regulate
the pressure for your comfort and safety.
|
|
INSTALLATION
1. Turn off the valve at the base of the wall as shown in Step
1.
2. Flush your toilet to drain the water from your toilet tank.
3. Disconnect the hose at the underside of the toilet
tank.
4. Install the T fitting as shown in Step 2.
5. Attach the valve to the outlet end of the T fitting as
shown in Step 3. Wrap the threads using the teflon tape.
6. Connect the hose to valve by placing the rubber gasket
between the nut and the valve. Tighten well.
7. Attach the hose to rinsing spray body. Be sure to insert
the rubber gasket. In some cases two gaskets will be required,
depending on the hand bidet.
8. Using the fastening set, insert the hanger at a convenient
height within easy reach as show in Step 4.
9. Test the rinsing spray to ensure there is no leakage.
|
|
STEP 1
|
STEP 2
|
|
|
|
STEP 3
|
STEP4
|
|
|
|
Note: In some instances the shutoff valve shown in the above images may be different.
USAGE SPECIFICATION
1. Water pressure should be between 0.05-0.30 Mpa (0.5-3.0
Kgf/cm2). This hand bidet is a low-pressure device, and for safety reasons not designed for high-pressure outlets.
2. Do not use toilet cleaners with hydrochloric acid content.
3. Do not use hard brush or steel wool for cleaning. Soft cloth or sponge is recommended to prevent scratch marks.
4. When tools are required for working with sanitary fittings, use thick cloth to prevent scratch marks.
5. When not in use, turn off the valve to avoid leakage.
|
|
Troubleshooting
|
Problem
|
Checkpoint
|
Solution
|
|
-
Cannot close water
|
1
|
Disassemble
and clean
|
|
-
Water leaks around water control plate
|
1
|
Disassemble
and clean
|
|
-
Water does not flow smoothly
|
2
|
Using
a cleaning pin by piercing through the hose of the
rinsing plate
|
|
-
No or low water flow
|
3
|
Disassemble
and clean
|
Note: The above drawing is representative of several different models. Individual hand bidet units may vary.
|
| |
| |
|
|